Home > Pole Line Hardware > ADSS Dead End Kits & Supports >

PLP FIBERLIGN® Dielectric Limited Tension Dead-end Only for ADSS 2872014 .890"-.945" to 2872019 1.213"-1.288"
PLP FIBERLIGN® Dielectric Limited Tension Dead-end Only for ADSS
 
Our Price: $51.40


Product Code: H-PLP-LIMTED-TEN-DEAD-END-ONLY


DEAD END ONLY RANGE/COLOR:


Qty:  
Description
 

Preformed Line Products FIBERLIGN® Dielectric Limited Tension Dead-end Only for ADSS
Dead-end component is required to transfer axial tensile loads and distribute radial compressive forces through the plastic jacket and onto the internal strength members without damaging the fragile plastic jacket or internal optical fibers.

ADSS Dead End ADSS Self Support

H-PLP2872014 .890" - .945", H-PLP2872015 .946" - 1.007", H-PLP2872016 1.008" - 1.073"
2872014, 2872015, 2872016
Features
  • In general, Limited Tension Dead-ends are intended for
  • use with these conditions and limitations:

  • • Low tensions, approximately:
  • - 1,000# (4.4kN) maximum initial (stringing/nominal
  • axial/long-term)
    tension
  • - 2,500# (11.1 kN) maximum loaded (working/loaded
  • axial/short-term) tension

  • • Short spans:
  • - 300' - 600' (91-183 m) typical maximum spans
  • depending upon cable OD and tensions
  • -
    not recommended for critical crossing spans (highways, rivers, etc.); see Medium or High Tension
  • Dead-ends

  • • Low strength cables

  • • “Standard” jackets
    • Most cable brands
    • No excessive operating conditions, cable motion or
  • high temperatures